{"id":7465,"date":"2018-06-06T07:31:10","date_gmt":"2018-06-06T05:31:10","guid":{"rendered":"https:\/\/aceautomation.eu\/stepper-motor-control-how-to-wire-easydriver-the-stepper-motor-driver\/"},"modified":"2018-07-27T13:50:11","modified_gmt":"2018-07-27T11:50:11","slug":"stepper-motor-control-how-to-wire-easydriver-the-stepper-motor-driver","status":"publish","type":"page","link":"https:\/\/aceautomation.eu\/es\/stepper-motor-control-how-to-wire-easydriver-the-stepper-motor-driver\/","title":{"rendered":"Stepper Motor Control \u2013 How to wire EasyDriver: The Stepper Motor Driver"},"content":{"rendered":"<p>[et_pb_section bb_built=&#8221;1&#8243;][et_pb_row][et_pb_column type=&#8221;4_4&#8243;][et_pb_text _builder_version=&#8221;3.9&#8243;]<\/p>\n<h2>Stepper Motor Control \u2013 How to wire EasyDriver: The Stepper Motor Driver<\/h2>\n<p>The EasyDriver is a simple to use stepper motor driver. Not really industrial, but can be use for test or DIY small machines.<br \/>\nIt will be connected to outputs of the Ace PLC and to the Stepper Motor. We will use the Motion Out Tool under vBuilder. The EasyDriver is compatible with stepper motor up to 30 VDC.<\/p>\n<p>Step Input and Direction input are compatible with 0 to 5V pulse. You can use your own power supply or the 5v output supply provide by the EasyDriver board which integrate a regulator 6-30 VDC (from Power In) to 5 VDC.<\/p>\n<p>Wiring the outputs of Ace PLC to the EasyDriver :<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-17706\" src=\"https:\/\/aceautomation.eu\/wp-content\/uploads\/stepper-easydriver-hardware-wire1.png\" alt=\"\" width=\"575\" height=\"355\" srcset=\"https:\/\/aceautomation.eu\/wp-content\/uploads\/stepper-easydriver-hardware-wire1.png 575w, https:\/\/aceautomation.eu\/wp-content\/uploads\/stepper-easydriver-hardware-wire1-300x185.png 300w\" sizes=\"(max-width: 575px) 100vw, 575px\" \/><\/p>\n<p>Note: The 5V output of the EasyDriver board is limited to 50mA. We suggest to use your own 5V power supply.<\/p>\n<p>Configuring, in the Setup Hardware section of vBuilder, the Step Out function of the PLC.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-17711\" src=\"https:\/\/aceautomation.eu\/wp-content\/uploads\/vbuilder_stepper-out31.png\" alt=\"\" width=\"834\" height=\"61\" srcset=\"https:\/\/aceautomation.eu\/wp-content\/uploads\/vbuilder_stepper-out31.png 834w, https:\/\/aceautomation.eu\/wp-content\/uploads\/vbuilder_stepper-out31-300x22.png 300w, https:\/\/aceautomation.eu\/wp-content\/uploads\/vbuilder_stepper-out31-768x56.png 768w, https:\/\/aceautomation.eu\/wp-content\/uploads\/vbuilder_stepper-out31-600x44.png 600w\" sizes=\"(max-width: 834px) 100vw, 834px\" \/><\/p>\n<p>And use the MotionOut function of vBuilder:<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-17716\" src=\"https:\/\/aceautomation.eu\/wp-content\/uploads\/vbuilder_motion_out1.png\" alt=\"\" width=\"597\" height=\"350\" srcset=\"https:\/\/aceautomation.eu\/wp-content\/uploads\/vbuilder_motion_out1.png 597w, https:\/\/aceautomation.eu\/wp-content\/uploads\/vbuilder_motion_out1-300x176.png 300w\" sizes=\"(max-width: 597px) 100vw, 597px\" \/><\/p>\n<p>All of this works on all Ace PLCs, from 49 \u20ac ex.Tax !<\/p>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p><div class=\"et_pb_row et_pb_row_0 et_pb_row_empty\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div> Stepper Motor Control \u2013 How to wire EasyDriver: The Stepper Motor Driver The EasyDriver is a simple to use stepper motor driver. Not really industrial, but can be use for test or DIY small machines. It will be connected to outputs of the Ace PLC and to the Stepper Motor. We will use the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_seopress_robots_primary_cat":"","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","_et_pb_use_builder":"on","_et_pb_old_content":"The EasyDriver is a simple to use stepper motor driver. Not really industrial, but can be use for test or DIY small machines.\r\nIt will be connected to outputs of the Ace PLC and to the Stepper Motor. We will use the Motion Out Tool under vBuilder. The EasyDriver is compatible with stepper motor up to 30 VDC.\r\n\r\nStep Input and Direction input are compatible with 0 to 5V pulse. You can use your own power supply or the 5v output supply provide by the EasyDriver board which integrate a regulator 6-30 VDC (from Power In) to 5 VDC.\r\n\r\nWiring the outputs of Ace PLC to the EasyDriver :\r\n\r\n<img class=\"alignnone size-full wp-image-2630\" src=\"http:\/\/aceautomation.eu\/wp-content\/uploads\/stepper-easydriver-hardware-wire.png\" alt=\"\" width=\"575\" height=\"355\" \/>\r\n\r\nNote: The 5V output of the EasyDriver board is limited to 50mA. We suggest to use your own 5V power supply.\r\n\r\nConfiguring, in the Setup Hardware section of vBuilder, the Step Out function of the PLC.\r\n\r\n<img class=\"alignnone size-full wp-image-2905\" src=\"http:\/\/aceautomation.eu\/wp-content\/uploads\/vbuilder_stepper-out3.png\" alt=\"\" width=\"834\" height=\"61\" \/>\r\n\r\nAnd use the MotionOut function of vBuilder:\r\n\r\n<img class=\"alignnone size-full wp-image-2636\" src=\"http:\/\/aceautomation.eu\/wp-content\/uploads\/vbuilder_motion_out.png\" alt=\"\" width=\"597\" height=\"350\" \/>\r\n\r\nAll of this works on all Ace PLCs, from 49 \u20ac ex.Tax !","_et_gb_content_width":"","footnotes":""},"class_list":["post-7465","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/aceautomation.eu\/es\/wp-json\/wp\/v2\/pages\/7465","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/aceautomation.eu\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/aceautomation.eu\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/aceautomation.eu\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/aceautomation.eu\/es\/wp-json\/wp\/v2\/comments?post=7465"}],"version-history":[{"count":3,"href":"https:\/\/aceautomation.eu\/es\/wp-json\/wp\/v2\/pages\/7465\/revisions"}],"predecessor-version":[{"id":17725,"href":"https:\/\/aceautomation.eu\/es\/wp-json\/wp\/v2\/pages\/7465\/revisions\/17725"}],"wp:attachment":[{"href":"https:\/\/aceautomation.eu\/es\/wp-json\/wp\/v2\/media?parent=7465"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}